Parallel Test of Midnight Blackbody Correction (MBCC)
|
Parallel Test of Midnight Blackbody Correction (MBCC)
-
Parallel (to operations) test of MBCC occurred Jan. 13-16, 2003, with data from GOES-10 Imager.
-
Parallel (MBCC) GOES-10 GVAR stream was distributed via the GOES-9 transponder.
-
Opn’l & parallel data were collected and compared at SSEC Data Center (U. Wisconsin)
-
The following two figures show their results for Jan. 14 & 15
-
The MBCC was effective from 0600 to 1000 UTC in Imager channels 2 (SW—3.8 :m),
3 (WV—6.7 :m), and 4 (LW—10.7 :m). (Local midnight for GOES-10 is at 0900 UTC.)
At those times, the MBCC increased the scene temperatures, as expected.
-
An unexpected “correction,” having opposite sign, was also made between
1000 and 1300 UTC in channels 3 and 4. This “correction” is not valid
and occurred because of an algorithm error. The error has since been corrected.
In the future, this invalid “correction” will not be made. (This catch
illustrates the benefits of parallel testing. We are greatly indebted
to our colleagues at U. Wisconsin.)